The wet air stream is split at the air dryer inlet through a differential valve. Part of this air / gas stream is passed through an external heater and heated to a regeneration temperature of 160-180°C, then it is fed to the desiccant tower under regeneration thus removing out the moisture from the desiccant bed. A water cooled / air cooled aftercooler condenses the desorbed moisture which is discharged regularly through the automatic drain . after condensation This stream joins the main incoming air stream and goes for drying to the other tower under drying. Normally a Cycle time of 6+6 hrs is utilised to complete one cycle of operation.
After each operation the changeover is effected automatically.
APPLICATIONS --- Instrument air dryers for power plants refineries , chemical & fertilizer plants etc.- CNG Compressed Natural Gas Drying Dryers.
SPECIFICATIONS FOR SPLIT
FLOW NO PURGE LOSS TYPE AIR DRYER
MODEL NO. |
CAPACITY |
PIPE LINE SIZE mm |
POWER CONSUMPTION KWH/DAY |
COOLING WATER REQT. LPM |
APROX. OVERRALL DIMENSIONS | |||
M³/
HR |
CFM |
LENGHT mm |
WIDTH mm |
HEIGHT mm | ||||
NPL-01 |
163.0 |
100 |
25 |
43.2 |
14 |
1600 |
1400 |
1800 |
NPL-02 |
244.5 |
150 |
25 |
64.8 |
21 |
1800 |
1500 |
2000 |
NPL-03 |
326.0 |
200 |
25 |
86.4 |
28 |
1800 |
1500 |
2000 |
NPL-04 |
489.0 |
300 |
40 |
129.6 |
42 |
2000 |
1500 |
2200 |
NPL-05 |
652.0 |
400 |
40 |
172.8 |
56 |
2000 |
1500 |
2200 |
NPL-06 |
815.0 |
500 |
50 |
216.0 |
70 |
2000 |
1800 |
2200 |
NPL-07 |
978.0 |
600 |
50 |
259.2 |
84 |
2200 |
1800 |
2400 |
NPL-08 |
1222.0 |
750 |
65 |
324.0 |
105 |
2400 |
1800 |
2400 |
NPL-09 |
1630.0 |
1000 |
65 |
432.0 |
140 |
2500 |
2000 |
2600 |
NPL-10 |
2037.0 |
1250 |
80 |
518.0 |
175 |
2500 |
2000 |
2800 |
NPL-11 |
2445.0 |
1500 |
80 |
648.0 |
210 |
2500 |
2000 |
3000 |
NPL-12 |
3260.0 |
2000 |
100 |
842.0 |
280 |
3000 |
2000 |
3000 |
NPL-13 |
4075.0 |
2500 |
100 |
1030.0 |
350 |
3000 |
2000 |
3000 |
The above air dryer capacities are rated at an inlet temp. of 40°C., 7kg/ Cm2g Pr. and at an outlet dew point of (-) 40°C. at Atm. Pressure, Supply Voltage of 415 V-3 PH- 50 HZ or 220V-1PH-50 Hz.
Above data is only for estimation and can be changed without notice. For special systems and higher capacities please contact us.
For cost comparison of operating of a Heat of Compression Type Air Dryers Vs. Heated Type/Heatless/Refrigerated Type Air Dryers please clickhere.
| OUR PRODUCT RANGES | |||
| PSA Nitrogen Generator (New !!!) | |||
| Air / Gas Dryers | |||
| Heatless Air Dryer | Refrigerated Air Dryer | ||
| Custom Made Air Dryer | High Pressure Air/Gas Dryer | ||
| Blower Heat Regenerated Air Dryer (BHR) | Internal Heater Dryer (IHR) | ||
| Heat of Compression Air Dryer (HOC) | Split Flow-No Purge Loss Air Dryer (SFNL) | ||
| Chillers | |||
| Air Cooled Water Chiller upto30Tr | Water Cooled Chiller up to 150Tr | ||
| Packaged Dry Air Plants | Liquid CO2 Storage Tanks | ||
| Packaged Dry Air Plant | Liquid CO2 Storage Tank | ||
| Refrigerants | |||
| Recovery System | |||
| Other Products | |||
| Auto Drain Trap | Air Receiver | Liquid Dryer | Walk in Cooler |
| Water Cooled After Cooler | Dew Point Apparatus | Hot Air Blowing Equipment | |
| Areawise Associates | Product Profiles | Corporate Info | Exhibitions | Customers | Approvals |
|
| |
| Copyright © 2002, Mellcon Engineers Pvt Ltd.. All Rights Reserved | |